运行电流(A)
|
2.0
|
2.3
|
2.5
|
3.0
|
3.2
|
3.5
|
4.0
|
4.2
|
D1
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
D2
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
ON
|
ON
|
ON
|
D3
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
D4
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
运行电流(A)
|
4.5
|
5.0
|
5.5
|
6.0
|
6.2
|
6.5
|
7.0
|
7.2
|
D1
|
ON
|
ON
|
ON
|
ON
|
ON
|
ON
|
ON
|
ON
|
D2
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
ON
|
ON
|
ON
|
D3
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
D4
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
细分数
|
200
|
400
|
800
|
1000
|
1600
|
2000
|
3200
|
4000
|
D5
|
ON
|
ON
|
ON
|
ON
|
ON
|
ON
|
ON
|
ON
|
D6
|
ON
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
D7
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
D8
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
细分数
|
5000
|
6400
|
8000
|
10000
|
12800
|
16000
|
20000
|
40000
|
D5
|
ON
|
ON
|
ON
|
ON
|
ON
|
ON
|
ON
|
ON
|
D6
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
D7
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
D8
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
D9
|
ON, 双脉冲:PU为正向步进脉冲信号,DR为反向步进脉冲信号
|
|||||||
OFF, 单脉冲:PU为步进脉冲信号,DR为方向控制信号
|
||||||||
D10
|
自动检测开关(OFF时接收外部脉冲,ON时驱动器内部以30转/分的速度运行)
|
标记符号
|
功能
|
注释
|
PU
|
输入信号光电隔离正端
|
接 5V供电电源, 5V- 24V均可驱动,高于 5V需接限流电阻。
|
PU-
|
DP9= OFF, PU为步进脉冲信号
|
下降沿有效,每当脉冲由高变低时电机走一步,输入电阻220Ω,要求:低电平0-0.5V,高电平4-5V,脉冲宽度>2.5μS。
|
DP9=ON, PU为正相步进脉冲信号
|
||
DR
|
输入信号光电隔离正端
|
接 5V供电电源, 5V- 24V均可驱动,高于 5V需接限流电阻。
|
DR-
|
DP9= OFF, DR为方向控制信号
|
用于改变电机转向。输入电阻220Ω,要求:低电平0-0.5V,高电平4-5V,脉冲宽度>2.5μS。
|
DP9=ON, DR为反向步进脉冲信号
|
||
MF
|
输入信号光电隔离正端
|
接 5V供电电源, 5V- 24V均可驱动,高于 5V需接限流电阻。
|
MF-
|
电机释放信号
|
有效(低电平)时关断电机接线电流,驱动器停止工作,电机处于自由状态。
|
V-
|
电源负极
|
电源:DC24-80V
|
V
|
电源正极
|
|
A
|
电机接线
|
|
A-
|
||
B
|
||
B-
|